2296 — D(S3) Dephasing Robustness Depends on Integer Lifts Not Only Residues
Result
For sector eigenvalue difference Delta, a common fractional timing or
amplitude error epsilon leaves exact residual
Its leading sensitivity depends on the full integer difference, not only its residue modulo eight. The frozen generator has 16 distinct nonzero absolute differences from 1 through 28 as catalogued in the result packet.
A common additive phase offset remains harmless. Branch-dependent phase errors obey
Weight bias contributes its discrete Fourier coefficient; the one-overweight
pattern has exact magnitude 8|eta|/7. Local amplitude/time errors propagate
through dtheta=t dJ+J dt+dJ dt into the exact leakage formulas.
Scope
These are coherent-error formulas and deterministic bounds. No stochastic hardware noise law or calibration-optimal integer lift is claimed.
Durable verification
- Packet:
research/kitaev/s3-timing-amplitude-phase-and-weight-errors.md - Checker:
uv run --with sympy python research/kitaev/checkers/check_s3_control_error_budget.py - Result:
research/kitaev/results/s3-control-error-budget.json - Eight aggregate gates pass
- Epistemic graph:
ev-000000003166-f5c7be00-3e03-400b-a270-b677ed09ee4f - Ledger allocation:
seqclaim-ca0541cea6bd2d954a311a19